The universally applicable process-controlled hand-held instruments, Series T900, are ideal for measuring operations in which high accuracy counts or the possibility of online documentation is demanded.
Characteristics
Measuring range: Pt100, according EN60751: -200°C...+850°C Thermocouple: according EN60584-1 (-200°C...+1760°C) Ohm: 0...400 Ohm Humidity: 0%...100%rF Flow: 0...40 m/s
Resolution: 0.01°C from -200°C...200°C, otherwise 0.1°C, 0.1%, 0.01 m/s
Accuracy: Pt100: ±0,03°C from -50°C...+199.99°C; ±0,05°C from -200°C...+200°C, otherwise 0,05% Thermocouple R, S: ±1,0°C +0,1 % Thermocouple K, J, L, N, T: ±0,3°C from 0°C...+200°C; ±1,0°C to 1000°C; ±1,5°C remaining range Humidity: ±1.5%rH Flow: 1% of end of value
Working temperature: 0°C...+40°C
Power supply: 230 VAC
Dimensions: 200 x 200 x 80 mm
Weight: 950 g
Possibilities
Inputs: 2-channel, Pt100, thermocouple: type K, J, L, N, R, S, T, humidity, dewpoint, flow
RS232 interface galvanically isolated
Optional SmartGraph Windows Software for graphic and tabular documentation
High accurate analog output (0-1 Volt)
High measuring accuracy
Integrated calibration function for simple compensation of sensor tolerances
Physical 1-point, 2-point or 3-point calibration function
Measuring channels are freely assignable
Recording maximum, minimum, hold and average values
Integrated sensor holder for one hand operation
Mains operation possible
Simultaneous display of two measured values
Differential temperature display
Packing
T955 bench instrument, 2-channel, Pt100, thermocouple, rel. humidity, dew point, air flow, without probe, without software
The universally applicable process-controlled hand-held instruments, Series T900, are ideal for measuring operations in which high accuracy counts or the possibility of online documentation is demanded.
Characteristics
Measuring range: Pt100, according EN60751: -200°C...+850°C Thermocouple, according EN60584-1: -200°C...+1760°C Ohm: 0...400 Ohm
Resolution: 0,1°C
Accuracy: Pt100: ±0,03°C from -100°C...+150°C; ±0,05°C from -200°C...+200°C, otherwise 0,1% Thermocouple R, S: ±1,0°C +0,1 % Thermocouple K, J, L, N, T: ±0,3°C from 0°C...+200°C; ±1,0°C to 1000°C; ±1,5°C remaining range
Working temperature: 0°C...+40°C
Power supply: 230 VAC
Dimensions: 200 x 200 x 80 mm
Width: 950 g
Possibilities
Inputs: 2-channel, Pt100, thermocouple: type K, J, L, N, R, S, T
RS232 interface galvanically isolated
Optional SmartGraph Windows Software for graphic and tabular documentation
High accurate analog output (0-1 Volt)
High measuring accuracy
Integrated calibration function for simple compensation of sensor tolerances
Physical 1-point, 2-point or 3-point calibration function
Measuring channels are freely assignable
Recording maximum, minimum, hold and average values
Integrated sensor holder for one hand operation
Mains operation possible
Simultaneous display of two measured values
Differential temperature display
Packing
T905 bench instrument, 2-channel, Pt100, thermocouple without probe, without software
The universally applicable process-controlled hand-held instruments, Series P600, are ideal for measuring operations in which high accuracy counts or the possibility of online documentation is demanded.
Characteristics
Measuring range: Pt100, according EN60751: -200°C...+850°C Thermocouple: according EN60584-1 (-200°C...+1760°C)
Accuracy: Pt100: ±0.1°C from -100°C...200°C, 0.1% remaining range Thermocouple R, S: ±1,0°C +0,1 % Thermocouple K, J, L, N, T: ±0,3°C from 0°C...+200°C; ±1,0°C to 1000°C; ±1,5°C remaining range
Resolution: 0,1°C remaining range
Working temperature: 0°C...+40°C
Power supply: 9 V battery
Dimensions: 200 x 85 x 40 mm
Weight: 300 g
Possibilities
RS232 interface galvanically isolated
Optional SmartGraph Windows Software for graphic and tabular documentation
High measuring accuracy
Integrated calibration function for simple compensation of sensor tolerances
Physical 1-point, 2-point or 3-point calibration function
Measuring channels are freely assignable
Recording maximum, minimum, hold and average values